DATA
|
DESCRIPTION OF DEFAULT ZONE TYPES
|
|
"1"
|
DAY ZONE - Instant when system is armed trouble zone when
system is disarmed.
|
|
"2"
|
24 HOUR AUDIBLE - Creates an instant yelping siren alarm
regardless of the armed state of the control panel.
|
|
"3"
|
ENTRY/EXIT DELAY 1- A trip will start entry delay 1. The lack
of a trip during exit delay will enable the Automatic Bypass or Instant
mode if so programmed.
|
|
"4"
|
FOLLOWER WITH AUTO- BYPASS DISABLED – This zone will be
instant when the system is armed and no entry or exit delays are being
timed. It is delayed during entry and exit delay times. This zone will
not automatically bypass even if enabled in Segment 1 of Location 23.
|
|
"5"
|
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED – This zone will
be instant when the system is armed and no entry or exit delay is being
timed. It is delayed during entry and exit delay times. This zone will
automatically bypass if enabled in Segment 1 of Location 23.
|
|
"6"
|
INSTANT - This zone creates an instant alarm when it is
tripped and the Armed LED is on.
|
|
"7"
|
24 HOUR SILENT - Creates an instant silent alarm regardless of
the armed state of the control panel. It will not display on the keypad.
|
|
"8"
|
FIRE - This zone will light the Fire LED and sound the
temporal siren each time the zone is shorted. It will also rapidly flash
the Fire LED indicating a trouble if the zone is open.
|
|
"9"
|
ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack
of a trip during exit delay will enable the Automatic Bypass or Instant
mode if so programmed.
|
|
"10"
|
24 HOUR SILENT SUPERVISED- Creates an instant silent alarm
regardless of the armed state of the control panel. It will display on
the keypad.
|
|
"11"
|
KEYSWITCH ZONE - This zone type will arm and disarm the
partition or partitions of the control panel that it resides in each
time the zone is shorted. Keyswitch arming will report as user #99.
|
|
"12"
|
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This
zone will be instant when the system is armed and no entry or exit delay
is being timed. It is delayed during entry and exit delay times. If a
"Cross Zone" is not being timed it will start a "Cross
Zone" timer. If a "Cross Zone" is being timed it will
create an instant alarm. This zone will automatically bypass when
enabled in Segment 1 of Location 23.
|
|
"13"
|
INSTANT ENTRY GUARD - This zone creates an instant alarm when
it is tripped and the Stay LED is off. It will start an entry delay time
1 if it is tripped and the system is armed and the Stay LED is on.
|
|
"14"
|
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will
start entry delay 1. This zone will bypass when the "Group
Bypass" command is entered at the keypad. The lack of a trip during
exit delay will enable the Automatic Bypass or Instant mode if so
programmed.
|
|
"15"
|
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will
be instant when the system is armed and no entry or exit delays are
being timed. It is delayed during entry/exit delay times. This zone will
bypass when the "Group Bypass" command is entered at the
keypad. This zone will automatically bypass if enabled in Segment 1 of
Location 23.
|
|
"16"
|
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an
instant alarm when it is tripped and the Armed LED is on. This zone will
bypass when the "Group Bypass" command is entered at the
keypad.
|
|
"17"
|
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start
entry delay 1. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed. This zone type can
be used to enable tamper on a wireless transmitter.
|
|
"18"
|
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This
zone will be instant when the system is armed and no entry or exit delay
is being timed. It is delayed during entry and exit delay times. This
zone will automatically bypass if enabled in Segment 1 of Location 23.
This zone type can be used to enable tamper on a wireless transmitter.
|
|
"19"
|
INSTANT WITH TAMPER ENABLED - This zone creates an instant
alarm when it is tripped and the Armed LED is on. This zone type can
be used to enable tamper on a wireless transmitter.
|
|
"20"
|
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry
delay 2. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed. This zone type can be used
to enable tamper on a wireless transmitter.
|