Auxiliary output event and time – Use the chart below to select the event that will activate each auxiliary output. Program the time from 0-255 (minutes or seconds, depending on data programmed in the special timing section. Programming a "0" makes the output follow the event.

AUXILIARY OUTPUT EVENT SELECTION

DATA

EVENT

DATA

EVENT

0

Burglary Alarm

26

Fire Trouble

1

Fire Alarm

27

Chime

2

24 Hour Alarm

28

Expander Trouble

3

Trouble Alarm

29

Dynamic Battery Test Time

4

Tamper Alarm

30

Open Period

5

Yelping Siren (Burglary)

31

Closed Period

6

Temporal Siren (Fire)

32

Listen-In

7

Any Siren

33

Line Seizure

8

Any Bypass

34

Ground Start

9

AC Fail

35

Fail To Communicate

10

Low Battery

36

Telephone Line Fault

11

Duress

37

Program Mode

12

Aux. 1 Keypad Zone

38

Download In Process

13

Aux. 2 Keypad Zone

39

Ground Fault

14

Panic Keypad Zone

40

Short Circuit (Over-current)

15

Keypad Tamper

41

Box Tamper

16

Autotest

42

Siren Tamper

17

Alarm Memory

43

Any Open

18

Entry

44

Any Short

19

Exit

45

Any Fault (Open/ Short on Non-Fire Zone)

20

Entry or Exit

46

Any Alarm

21

Armed State

47

Beeping Keypad

22

Disarmed State

48

Code Entry (See note below)

23

Ready

49

Key FOB Function 1

24

Not Ready

50

Key FOB Function 2

25

Fire

   
 
FALSE ALARM PREVENTION

The Power of One (1.8MB PDF)

Networx Brochure (418KB PDF)

NX Series Feature Comparision Sheet (86KB PDF)